Rancang Bangun Sistem Pentanahan Penangkal Petir Pada Tanah Basah dan Tanah Kering pada Laboratorium Teknik Konversi Energi Design of Ground Lightning Protection System in Wet and Dry Soils in Energy Conversion Engineering Laboratory

Main Article Content

Herman Nawir
Muhammad Ruswandi Djalal
Sonong Sonong

Abstract

Lightning rods in the Laboratory of Energy and Protection Distribution System of Ujung Pandang State Polytechnic are not functioning properly so the resistance resistance tends to be large, this is not good for earthing. This problem can be overcome by remaking lightning rods on wet and dry soils. This activity was carried out to reduce the value of resistance resistance in connection with this, this activity was carried out by designing, assembling and collecting data carried out by testing, while data analysis was carried out by counting. Based on the results of the discussion concluded that the resistance resistance value obtained is smaller than the previous device. Evidenced by the results of the test where the resistance value on the rod electrode in dry conditions ranged from 1.56 to 2.40 Ohm while the previous tool ranged from 1.6 to 9.0 Ohm. Then for wet soil conditions that range from 0.45 to 1.29 Ohm, while the previous tool is around 1.8 - 5.25 Ohm

Article Details

Section
Electric Power Regulatory System

References

[1] I. Puspitasari, & Supardiyono, "Analisa Pemetaan Kontur dan Kerapatan Petir dengan Lightning 2000 dan Metode Kriging di Surabaya Tahun 2000.," Jurnal Fisika, vol. 3, pp. 39-45, 2014.

[2] S. A. Arifin, Andi, "Pembuatan Penangkal Petir Dengan Menggunakan Sistem Pentanahan Batang Dan Plat," Laporan Tugas Akhir. Makassar: Jurusan Teknik Mesin Politeknik Negeri Ujung Pandang., 2009.

[3] U. S. Atmam, "Perancangan Kinerja Penangkal Petir Menggunakan Metoda Bola Gelinding Pada Gedung Perpustakaan Universitas Lancang Kuning Pekanbaru," Jurnal Sains, Teknologi dan Industri, vol. 13, pp. 130-135, 2015.

[4] D. Djoko, "Sistem Proteksi Petir dan Sistem Penangkal Petir, PT.Tritech Consult," 1995.

[5] G. T. Suprijono, Muhammad, "Sitim Penangkal Petir Pada INstalasi Vital Atau Gedung Bertingkat Di PT. Telkom Tegal," Program Studi Teknik Elektro, Politeknik Harapan Bersama Tegal, 2014.

[6] M. H. C. Hamdani, M. Dwi. (2014). Standar Nilai Resistan Pembumian Grounding. Available: http://ahlipenangkalpetir.blogspot.co.id/2014/01/standar-nilai-resistan-pembumian-grounding.html

[7] T. Suyamto, Idrus Abdul Kudus, "EVALUASI DAN PERENCANAAN GROUNDING UNTUK PENANGKAL PETIR GEDUNG SIKLOTRON," presented at the Prosiding Pertemuan dan Presentasi Ilmiah Teknologi Akselerator dan Aplikasinya, 2015.

[8] A. Sanusi, "Rancang Bangun Pentanahan Elektroda Rod dan Plat Pada Laboratorium Teknik Konversi Energi," Laporan Tugas Akhir Jurusan Teknik Mesin Politeknik Negeri Ujung Pandang 2007.

[9] A. M. S. Y. d. A. P. Makmur Saini, "Pengembangan Sistem Penangkal Petir dan Pentanahan Elektroda Rod dan Plat," Jurnal INTEK, vol. 3, pp. 66-71, 2016.

[10] M. Rajagukguk, "Studi Pengaruh Jenis Tanah dan Kedalaman Pembumian Driven Rod terhadap Resistansi Jenis Tanah," Jurusan Teknik Elektro, Universitas Tanjungpura, 2012.

[11] I. S. 81, IEEE guide for measuring Earth Resistivity Ground Impedance and earth Surface Potentials of a grounding System, 1983.