Penempatan Kapasitor Shunt Pada Sistem Kelistrikan 150 Kv Sulselrabar Shunt Capacitor Placement in Sulselrabar 150 Kv Electrical System

Main Article Content

Muhammad Ruswandi Djalal
Herman Herman

Abstract

Power flow study is the determination or calculation of the voltage, current and power factor or reactive power that is present at various points in a power grid in the normal state, whether current or expected to occur in the future. From the result of normal condition analysis, it is obtained the critical voltage profile on bus 31 tonasa and used as the candidate for mounting capacitor. From the calculation results obtained capacities installed 16.0413 Mvar. From the simulation results before the installation and after installation of the capacitor visible improvement of voltage profile and channel losses. The channel losses prior to installation are 32,649 MW and after installation of 31,834 MW. For voltage profiles, some buses also look better, than before in critical conditions to be marginal. On the previous bus tonasa 0.933 pu to 0.953043 pu

Article Details

Section
Electric Power Regulatory System

References

[1] H. Agil and M. R. Djalal, "Studi Hubung Singkat 3 Fasa Simetri (Studi Kasus Sistem Interkoneksi 150 kV Sulselrabar)," presented at the Nasread Universitas Darul 'Ulum Jombang, Teknik Elektro Universitas Darul 'Ulum Jombang, 2014.

[2] M. R. Djalal, M. A. Haikal, T. M. P. N. U. Pandang, and T. E. I. P. Aceh, "Penyelesaian Aliran Daya 37 Bus Dengan Metode Newton Raphson (Studi Kasus Sistem Interkoneksi 150 kV Sulawesi Selatan)," 2014.

[3] M. R. Djalal, "Penempatan PSS pada System Kelistrikan 150 kV Sulselrabar menggunakan Cuckoo Search Algorithm," Tesis ITS, 2015.

[4] M. R. Djalal and Faisal, "Intelligent Fuzzy Logic-Cuckoo Search Algorithm Method for Short-Term Electric Load Forecasting in 150 kV Sulselrabar System," Lontar Komputer: Jurnal Ilmiah Teknologi Informasi, vol. 8, pp. 154-165, 2017.

[5] M. R. Djalal, A. Imran, and I. Robandi, "Optimal placement and tuning power system stabilizer using Participation Factor and Imperialist Competitive Algorithm in 150 kV South of Sulawesi system," in Intelligent Technology and Its Applications (ISITIA), 2015 International Seminar on, 2015, pp. 147-152.

[6] M. R. Djalal, H. Nawir, H. Setiadi, and A. Imran, "An Approach Transient Stability Analysis Using Equivalent Impedance Modified in 150 kV South of Sulawesi System," Journal of Electrical and Electronics Engineering UMSIDA, vol. 1, pp. 1-7, 2016.

[7] M. R. Djalal, M. Y. Yunus, H. Nawir, and A. Imran, "Application of Smart Bats Algorithm for Optimal Design of Power Stabilizer System at Sengkang Power Plant," International Journal of Artificial Intelligence Research, vol. 1, 2017.

[8] M. R. Djalal, M. Y. Yunus, H. Nawir, and A. Imran, "Optimal Design of Power System Stabilizer In Bakaru Power Plant Using Bat Algorithm," 2017, vol. 1, p. 6, 2017-11-10 2017.

[9] I. Gunadin, Y. S. Akil, Sirajuddin, and M. R. Djalal, "Application Fuzzy Logic-Cuckoo Search Algorithm for Load Forecasting in 150 kV Sulselrabar Electric Power System," presented at the The 2nd International Conference on Education, Science, and Technology (ICEST) 2017, Four Points by Sheraton, 2017.

10] M. Hidayat, Y. S. Akil, I. Gunadin, and M. R. Djalal, "Short-Term Electricity Demand Forecasting using Fuzzy Logic-Flower Pollination Algorithm (FL-FPA)," presented at the The 2nd International Conference on Education, Science, and Technology (ICEST) 2017, Four Points by Sheraton, 2017.

[11] M. Y. Yunus, M. R. Djalal, and Marhatang, "Optimal Design Power System Stabilizer Using Firefly Algorithm in Interconnected 150 kV Sulselrabar System, Indonesia," International Review of Electrical Engineering (IREE), vol. 12, pp. 250-259, 2017.